Vibration
The FDR-1000 PC is
qualified according to MIL-STD-810F for airborne, land Mobile and Naval
environment.
Airborne
Test on 3 axes (transverse.
Longitudinal, vertical)
per Mil Std 810F / Method
514.5 / Fig. 514.5C-9
Frequency Range 15-2000 Hz.
Vibration level on each axis 4.8 Grms
Land Mobile
Test on 3 axes (transverse. Longitudinal,
vertical)
per Mil Std 810F / Method
514.5 / Fig 514.5C-3
frequency range: 5-500 Hz.
Transverse - 1.53 g rms
Longitudinal - 1.96 g rms
Vertical – 1.683 g rms
Sand and
Dust
The FDR-1000 PC shall
operate as specified herein while and after being subjected to sand and
dust as encountered in dry arid arias. The FDR-1000 PC shall meet the
requirements specified in MIL-STD-810F.
Salt Fog
The FDR-1000 PC is
resistant to the corrosive effects of salt fog environment. The
FDR-1000 PC meets the requirements specified in MIL-STD-810F Method 509.3
Procedure I. The base metal shall not be visible through the finish
or coating, nor shall be any evidence of blistering, softening,
separation from the base metal, corrosion products, or other coating
failure.
Relative humidity
The FDR-1000 PC, in an
operating or non operating condition, shall not be affected by
humidity for both continuous and intermittent periods,
including conditions wherein condensation takes place in and on the
equipment in the form of water. The FDR-1000 PC meets the
requirements specified in MIL-STD-810F.
Operating - 95% RH with no
condensation.
Non-operating - 95% RH.
Fungus
The FDR-1000 PC
is non-nutrient to fungus growth per the requirements specified in
MIL-STD-810F.
RFI/EMI
FDR-1000 complies to MIL-STD-461E.
- CS101 Conducted Susceptibility,
Power Leads, 30HZ-150KHz.
- CE101 Conducted Emissions,
Power Leads, 30Hz - 10kHz
- CE102 Conducted Emissions, Power Leads,
10kHz - 10MHz
-
RE102 -
Radiated Emissions, 10 KHz to 18 GHz
- RS103 -
Radiated Susceptibility, Electric
Field, 2MHz
–18GHz
- CS114 -
Conducted
susceptibility, bulk current injection,
10KHZ - 200 MHZ.